Outside Lighting - NEMA Beam Spread Classifications

 

The light distribution of a floodlight is referred to as "beam spread" and is classified by its "NEMA type".  The NEMA beam spread indicates the two edges where the light intensity photometric spreads horizontal and vertical to 10% of the maximum beam intensity.

For example:

 
 

Asymmetrical beam spread

138° (H)   x

  119° (V)

Horizontal   

   Vertical

= NEMA 7 x 6

 

NEMA Beam Spread Classifications

Beam Spread Degrees

NEMA Type

Beam Description
10° up to 18° 1 very narrow
18° up to 29° 2 narrow
29° up to 46° 3 medium narrow
46° up to 70° 4 medium
70° up to 100° 5 medium wide
100° up to 130° 6 wide
130° and up 7 very wide
 